Users Guide
Introduction
The Irritrol R-100-KIT Remote Control Set works with a variety
of irrigation systems, allowing the user to remotely control
compatible controllers and the watering zones. The user can
walk the landscape site, testing, troubleshooting, and/or pro-
viding supplemental watering.
The R-100-KIT Remote Set contains a remote transmitter, a
mini-receiver, and an adapter cable. The Set allows the user to
plug the mini-receiver unit into a variety of irrigation control-
lers. The CL-R1, transmitter only, works with the Irritrol CLIMATE
LOGIC® without the need for the mini-receiver.
This manual explains the installation of the R-100-KIT and cov-
ers the use and operation the remotes have in common.
• Battery Installation
• Connecting the Mini-receiver
• Transmitter Controls
• The LCD Screen
• Setting the PIN
• General Operation
• Unique Lighting Control
R-100-KIT Components
• CL-R1 Remote
Transmitter
• CL-MR Mini-receiver
• CMR-ADP Adapter
cable (not pictured)
English Español Français
Page view 0
1 2 3 4 5 6 ... 35 36

Summary of Contents

Page 1 - & CL-R1

CL-R1Cancel EnterPWR (Hold)SetupR-100-KIT & CL-R1Remote Control User’s GuideIntroductionThe Irritrol R-100-KIT Remote Control Set works with a va

Page 2 - The CL-R1 and Climate Logic

10To Run an All Stations Cycle (ASC):Running an All Stations Cycle is useful for troubleshooting a sprinkler system. 1. Start a Program (section a

Page 3 - The Adapter Cable (CMR-ADP)

11Unique Lighting ControlAs an allied brand to Irritrol in the landscaping industry, Unique Lighting oers remote control of its landscape lighting pr

Page 4

FCC StatementThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Page 5

CL-R1Cancel EnterPWR (Hold)SetupR-100-KIT y CL-R1Control remoto Guía del usuarioIntroducciónEl Sistema de control remoto Irritrol R-100-KIT funciona

Page 6

14CompatibilidadEn la actualidad el R-100-Kit puede funcionar de forma remota con ocho (8) series de programadores. Irritrol irá añadiendo más seri

Page 7 - Setting the PIN

15El cable adaptador (CMR-ADP)El minirreceptor tiene un cable RJ-11 conectado. La mayoría de los programadores compatibles tienen un conector RJ-11 pa

Page 8

16EARTHGROUNDMV/PumpSensor+-7 8 9 10 11 121 2 3 4 5 624 VACVCConexión del receptor a un programadorEl alcance del control remoto al minirreceptor e

Page 9 - General Operation

17Conexión con modelos antiguos de los programadores MC-E “Blue”:1. Abra el panel frontal del programador.2. El conector de 5 pines está situado ent

Page 10

18Controles del transmisor remotoCL-R1Cancel EnterPWR (Hold)SetupTecla Setup (Conguración)Flecha IzquierdaTapa USB (para uso futuro)Tecla Cancel (

Page 11 - Unique Lighting Control

19Establecimiento del número PINDespués de conectar el receptor, es necesario establecer el número PIN en el transmisor y en el receptor. Establezca p

Page 12 - FCC Statement

2CompatibilityAt this point, there are eight (8) series of controllers with which the R-100-Kit can remotely operate. Irritrol will add more series

Page 13 - R-100-KIT y CL-R1

20Para establecer el PIN en el módulo receptor de Climate Logic:1. Después de establecer el PIN en el transmisor (ver arriba), abra el módulo rece

Page 14 - El CL-R1 y Climate Logic

21Instrucciones generales de usoPara encender el transmisor remoto:1. Pulse la tecla roja MODE/PWR para encender el aparato. 2. Mantenga pulsada l

Page 15 - El cable adaptador (CMR-ADP)

22Para utilizar All Stations Cycle (ASC) (Arranque cíclico de todas las estaciones):Esta función es útil para localizar problemas en un sistema de

Page 16 - 1 2 3 4 5 6

23Control remoto de Unique LightingComo marca aliada de Irritrol en el sector de la jardinería, Unique Lighting ofrece sistemas de control remoto para

Page 17

24 Declaración FCCEste equipo ha sido probado y se ha vericado que cumple los límites de un dispositivo digital de la Clase B, conforme con la p

Page 18 - PWR (Hold)

CL-R1Cancel EnterPWR (Hold)SetupR-100-KIT & CL-R1Système de commande à distance Guide de l’utilisateurIntroductionLe système de commande à distan

Page 19

26CompatibilitéÀ ce stade, huit (8) séries de programmateurs peuvent être commandées à distance avec le système R-100-Kit. Irritrol ajoutera d’autr

Page 20

27Le câble adaptateur (CMR-ADP)Le mini-récepteur possède un câble RJ-11 xe. La plupart des programmateurs possèdent un port RJ-11 pour ce câble. Tout

Page 21

28EARTHGROUNDMV/PumpSensor+-7 8 9 10 11 121 2 3 4 5 624 VACVCConnexion du récepteur à un programmateurLe mini-récepteur a une portée optique jusqu’

Page 22

29Connexion aux anciens modèles de programmateurs MC-E “Bleus”:1. Ouvrez le panneau avant du programmateur.2. Le connecteur à 5 broches se trouve e

Page 23

3The Adapter Cable (CMR-ADP)The Mini-receiver has an attached RJ-11 cable. Most compatible controllers have an RJ-11 port for this cable. Early models

Page 24 - Declaración FCC

30Commandes de la télécommandeCL-R1Cancel EnterPWR (Hold)SetupBouton SETUP (conguration)Flèche vers la gaucheCache de prise USB (future utilisatio

Page 25

31Programmation du code PINAprès avoir connecté le récepteur, il est nécessaire de programmer le code PIN dans la télécommande et le récepteur. Commen

Page 26 - CL-R1 et Climate Logic

32Pour programmer le code PIN dans le module récepteur Climate Logic:1. Après avoir programmé le code PIN dans la télécommande portable (voir plu

Page 27 - Le câble adaptateur (CMR-ADP)

33Fonctionnement généralPour mettre la télécommande sous tension:1. Appuyez sur le bouton MODE/PWR rouge pour activer la télécommande. 2. Appuyez

Page 28

34Pour exécuter un cycle toutes voies (ASC):L’exécution d’un cycle toutes voies est utile pour dépanner un système d’arrosage. 1. Lancez un progr

Page 29 - Français

35Commande Unique LightingEn tant que marque aliée à Irritrol dans le secteur du paysagement, Unique Lighting ore la possibilité de commander à dist

Page 30

36 Déclaration de la FCCCet équipement a été testé et trouvé conforme aux restrictions imposées aux appareils numériques de Classe B en vertu de

Page 31 - Programmation du code PIN

4EARTHGROUNDMV/PumpSensor+-7 8 9 10 11 121 2 3 4 5 624 VACVCConnecting the Receiver to a ControllerThe range of the Mini-receiver to the Remote is

Page 32

5Connecting to early models of MC-E “Blue” controllers:1. Open the front panel of the controller.2. The 5-pin connector is sandwiched between the fr

Page 33 - Fonctionnement général

6Remote Transmitter ControlsCL-R1Cancel EnterPWR (Hold)SetupSetup buttonLeft arrowUSB Cover (future use)Cancel buttonDown arrowLCD ScreenUp arrowPo

Page 34

7Setting the PINAfter connecting the receiver, it is necessary to set the PIN in the transmitter and receiver. Set the PIN in the transmitter rst. To

Page 35 - Commande Unique Lighting

8To Set the PIN in the Climate Logic Receiver Module:1. After setting the PIN in the handheld transmitter (see above), open the Climate Logic rece

Page 36 - Déclaration de la FCC

9General OperationTo Power the Remote Transmitter:1. Press the red MODE/PWR button to turn on. 2. Press and hold MODE/PWR button (about two sec

Comments to this Manuals

No comments